| 266 CMR 6.00: Standards of Practice
Source: The Division
of Professional Licensure
6.01: Access
6.02: Purpose
6.03: General Requirements
6.04: Scope of the Home Inspection
6.05: General Limitations and Exclusions of the Home Inspection
6.06: Prohibitions
6.07: Optional Fee Based Services
6.01: Access
The Client shall provide Safe Access and Sufficient Lighting to
ensure that all systems and areas to be inspected under this standard
are Readily Accessible and Observable.
6.02: Purpose
(1) The purpose of a Home Inspection for Residential Buildings,
including their attached garages, is to provide the Client with
an inspection Report that forthrightly discloses the physical conditions
of the systems and components listed in 266 CMR 6.04 which are
Readily Accessible and Observable, including those systems and
components, which are Safety Hazards as Observed at the time of
the inspection.
(2) An inspection carried out under the standards of 266 CMR 6.04
is not and shall not be construed to be a comprehensive Architectural
and/or an Engineering study of the dwelling in question.
6.03: General Requirements
(1) Inspectors shall:
(a) Use a written contract and provide only the Client with an
original copy of the contract unless otherwise directed by the
Client.
(b) Observe Readily Accessible and Observable installed systems
and components listed in 266 CMR 6.04.
(c) Submit a confidential written Report only to the Client, which
shall:
1. Identify those components specified to be identified in 266
CMR 6.04.
2. Indicate which systems and components designated for inspection
in 266 CMR 6.04 have not been inspected.
3. Indicate the condition of systems and components so Inspected
including those that were found to be in need of repair, require
additional investigation, and areas that have a potential for concealed
damage.
4. Record the Inspector's name (and the Trainee's name if applicable).
5. Record the Client's name and the address of the property inspected.
6. Record the on-site Inspection start and finish times.
7. Record the weather conditions at the time of the inspection.
8. Record the existence of obstructions and/or conditions that
prevented the inspection of the installed systems and components.
9. Embed in the Report and/or attach to the Report the list of
itemized questions in 266 CMR 6.03(4)(a) through (k).
10. Embed in the Report and/or attach to the Report a copy of
266 CMR 2.00: Definitions and a copy of the 266 CMR 6.00: Standards
of Practice.
(2) Every registered professional Home Inspector may have a seal
of the design shown below authorized by the Board. All Reports
prepared by a registered Home Inspector, or under his supervision,
may be stamped with the impression of such seal and/or bear the
name and license number of the Home Inspector. A registered Home
Inspector shall impress his seal on and/or attach his name and
license number to a Report only if his/her certificate of registration
is in full force, and if he/she is the author of such Report or
is in charge of its' preparation.
(3) The Report shall only inform the Client if additional investigation
is required when:
(a) The scope of the repair(s) is unknown, or
(b) There is potential for and it is suspected that there is concealed
damage, or
(c) The subject area is beyond the scope of the Home Inspector's
expertise.
(4) The Inspector shall notify his/her Client that answers to
the following questions should be ascertained from the Seller and/or
the Seller's Representative because they are important and relevant
to the purchase of the inspected dwelling and may not be Readily
Observable through inspection. The Inspector shall have been deemed
to satisfy this requirement by embedding and/or attaching the questions
listed in 266 CMR 6.03(4)(a) through (k) to the Report.
To the Best of Your Knowledge as the Seller and/or Seller's Representative:
(a) Does the dwelling have a history of seepage, dampness, and/or
water penetration into the Basement and/or Under Floor Crawl Space?
If so please explain.
(b) Has a sump pump ever been installed or used in the Basement/Under
Floor Crawl Space?
(c) Do you use any type of dehumidification in any part of the
dwelling?
(d) Are you aware of any mold and/or air quality issues in the
dwelling?
(e) Is the dwelling on a private sewage system?
1. If the waste system is private, has a Title V inspection been
completed, and is the completed Title V Report available for review?
2. Has the dwelling ever been inspected and/or treated for insect
infestation?
a. If so, when?
b. What were the chemicals used?
(f) Has the dwelling ever been tested for radon gas and/or lead
paint?
1. If so when?
2. What were the results?
(g) Has the dwelling ever been inspected by an Inspector?
1. If so, when?
2. Were any problems noted?
3. Is a copy of the inspection Report available?
(h) Are the Seller/ Seller's Representative aware of any structural,
mechanical, electrical or other material defects that may exist
on the property?
(i) Has there ever been a fire in the dwelling?
1. If so, when?
2. What areas were involved?
3. What chemical cleaners, if any, were used for cleanup?
(j) Has there ever been a hazardous waste spill on the property?
(k) Is there is an underground storage tank on the property?
(5) The Inspector shall not represent to the Seller/Seller's Representative
or Client that there is any legal obligation, duty, or requirement
on behalf of the Seller/Seller's Representative to answer the questions
set forth in 266 CMR 6.03(4)(a) through (k).
(6) The Inspector shall not be held liable for the accuracy of
third party information.
(7) Regardless of any additional professional registrations or
licenses held by the Inspector and/or Trainee practicing in the
Commonwealth of Massachusetts he/she shall conduct his/her Home
Inspection in accordance with 266 CMR 6.00 through 6.06. However,
the standards are not intended to limit Inspectors from:
(a) Reporting observations and conditions in addition to those
required in 266 CMR 6.04.
(b) Excluding other systems and components from the inspection
if requested by the Client and noted in the Report.
(c) Providing Optional Fee Based Services, as long as they are
contracted for in writing and/or included in the report and are
not prohibited under 266 CMR 6.06.
Top
6.04: Scope of the Home Inspection
(1) System: Roofing.
(a) The Inspector shall Observe the Readily Accessible and Observable:
1. Roof coverings.
2. Exposed roof drainage systems
3. Flashings.
4. Skylights, chimneys, and roof penetrations.
5. Signs of leaks on building components.
(b) The Inspector shall Identify:
1. the type of roof covering materials: Asphalt, Cementious, Slate,
Metal, and/or Tile Shingles, Built-up type (Bald Asphalt, Tar and
Gravel, Mineral Covered Rolled Roofing, Ballasted Rubber Membrane,
Adhered Membrane, Mechanically Fastened Membrane, Other.
2. the roof drainage system: Gutters (Aluminum, Copper, Wood,
Vinyl, Other) Leaders/Downspouts (Aluminum, Copper, Galvanized,
Vinyl, Other)
3. the chimney materials: Brick, Concrete Block, Metal, Other
4. the methods used to Observe the roofing.
(c) The Inspector shall Report on:
1. Any signs of previous and/or active leaks.
2. The following exposed Readily Accessible and Observable roofing
components: the roof covering, exposed roof drainage systems, exposed
flashings, skylights, exterior of chimney(s), roof penetrations.
(d) Exclusions: Including but not limited to 266 CMR 6.04(d)1.
and 2., the Inspector shall not be required to:
1. Walk on the roof unless in the opinion of the Home Inspector
he/she is provided Safe Access, and the Seller and/or the Seller's
Representative provides authorization that relieves the Inspector
of all liability of possible damage to the roofing components,
and in the opinion of the Inspector, walking on the roof will pose
no risk of personal injury or damage to the roofing components.
2. Observe and Report On:
a. Attached accessories including, but not limited to: solar systems,
antennae, satellite dishes and lightning arrestors.
b. The interior of chimney flues.
Top
(2) System: Exterior.
(a) The Inspector shall Observe the Readily Accessible and Observable:
1. Wall cladding.
2. Entryway doors and windows.
3. Garage door operators.
4. Decks, balconies, stoops/landings, steps, areaways/window wells,
and porches including hand and guard railings.
5. Exposed trim (eaves, soffits, fascias, rake, corner, and other
trim Boards).
6. Flashings
7. Driveways, walkways, vegetation, grading, site drainage, and
retaining walls.
(b) The Inspector shall Identify:
1. Wall-cladding materials: Cementious Siding, Asphalt and/or
Wood Shingles, Aluminum and/or Vinyl Siding, Wood Clapboards, Brick,
Other.
2. The deck/porch component materials: Brick, Concrete, Concrete
Block, Steel, Wood, Other.
(c) The Inspector shall Report On the following exposed Readily
Accessible and Observable exterior components:
1. Wall cladding.
2. Entryway doors and windows.
3. Deck/porches, balconies, stoops/landings, steps, areaways/window
wells, including hand and guard railings.
4. The exposed trim.
5. Flashings.
6. Driveways, walkways, and retaining walls with respect to their
effect on the condition of the dwelling and their ability to provide
safe egress.
7. Vegetation, grading, site drainage with respect to their effect
on the condition of the dwelling.
(d) The Inspector shall:
1. Probe exposed Readily Accessible and Observable exterior components
where deterioration is suspected: However, probing is NOT required
when probing would unduly damage any finished surface.
2. Operate all entryway doors and representative number of windows
and Report their condition and need of repair, if any.
3. Operate garage doors (if the garage is attached to the main
dwelling), manually or by using permanently installed controls
of any garage door operator.
4. Report whether or not any garage door operator will automatically
reverse or stop when meeting resistance during closing.
(e) Exclusions: Including but not limited to 266 CMR 6.04(2)(e)1.
through 9., the Inspector shall not be required to Observe and
Report On the following:
1. Storm doors and windows, screening, shutters, awnings and similar
seasonal accessories.
2. Fences, landscaping, trees, swimming pools, patios, sprinkler
systems.
3. Safety glazing.
4. Geological conditions (Engineering services).
5. Soil conditions (Engineering services).
6. Recreational facilities.
7. Any other dwelling units or addresses in multi-unit buildings.
8. Outbuildings and detached garages. However, should the Inspector
include the inspection of these structures, under 266 CMR 6.07:
Optional Fee Based Services, the inspection must comply with the
standards of 266 CMR 6.04.
9. Underground utilities, pipes, buried wires, or conduits (Dig
Safe)
Top
(3) System: Structural Components Exposed in the Basement/Under
Floor Crawl Space and Attic Space; Including Signs of Water Penetration.
(a) Basement/Under Floor Crawl Space:
1. The Inspector shall Observe the following exposed Readily Accessible
and Observable Basement/Under Floor Crawl Space structural components:
a. The exposed portions of the foundation.
b. The exposed portions of the Basement/Under Floor Crawl Space
floor.
c. The exposed portions of the superstructure system (girders,
sills, floor joists, headers, and sub-floor).
d. The exposed portions of the columns and posts.
2. The Inspector shall Identify:
a. The type of exposed Basement foundation materials (brick, concrete
block, concrete, stone, wood, other).
b. The type of exposed Basement floor system (concrete, earth,
wood, other).
c. The type of exposed Basement superstructure system (girder(s),
sills, floor joists, and sub-floor).
d. The type of exposed Basement columns and posts (brick, concrete
block, concrete, steel, wood, other).
3. The Inspector shall Report On the following exposed Readily
Accessible and Observable structural components:
a. The foundation.
b. The floor system.
c. The superstructure system.
d. The columns and posts
4. The Inspector shall:
a. Probe exposed Readily Accessible and Observable structural
components where deterioration is suspected; however, probing is
NOT required when probing would unduly damage any finished surface.
b. Note the methods used to Observe Under Floor Crawl Spaces.
c. Note obstructions, unsafe access, and dangerous or adverse
situations that prevented him/her from inspecting the items noted
in 266 CMR 6.04(3)(a)3.a. through d..
d. Note signs of previous and/or active water penetration into
the Basement, Under Floor Crawl Space and attic including the presence
of sump pumps and dehumidifiers.
5. Exclusions: Including but not limited to 266 CMR 6.04(3)(a)5.a.
through d., the Inspector shall not be required to:
a. Collect engineering data such as the size, span, spacing, species,
section modulus, slenderness ratio and/or modulus of elasticity
of the structural members.
b. Provide access to the items being inspected (Responsibility
of Client/ Seller/Seller's Representative).
c. Enter the Under Floor Crawl Space
i. If it is not Readily Accessible,
ii. If access is obstructed and/or if entry could damage the property
iii. If a Dangerous or Adverse Situation is suspected and Reported
by the Inspector.
d. Observe and Report On Wood destroying insects, rodents and/or
vermin unless specifically contracted for in writing. (Independent
Pest Control/Extermination Service).
(b) Attic Space.
1. The Inspector shall Observe the following exposed Readily Accessible
and Observable roof framing structural components: The exposed
portions of the roof framing, including the roof sheathing.
2. The Inspector shall Identify:
a. The type of framing: Rafters, Collar Ties, Tie Beams, Trusses,
Other
b. Roof Sheathing: Boards, Oriented Strand Board, Plywood, Other.
c. The methods used to Observe attics (through a hatch or while
standing in the attic space).
3. The Inspector shall Report On:
a. The presence and/or lack of flooring, obstructions, unsafe
access, and dangerous or adverse situations that prevented him/her
from inspecting the items noted in 266 CMR 6.04(3)(b)2.
b. The following exposed Readily Accessible and Observable structural
components of the roof framing:
i. The roof framing (Rafters, Collar Ties, Tie Beams, Rafter Ties,
Trusses, Beams, Other)
ii. Sheathing Materials (Boards, Oriented Strand Board, Plywood,
Other).
c. The presence of a light.
4. The Inspector shall:
a. Probe exposed Readily Accessible and Observable structural
components where deterioration is suspected: However, probing is
NOT required when probing would unduly damage any finished surface.
b. Note the presence of a light.
c. Note the presence of collar ties and/or tie beams.
5. Exclusions: Including but not limited to 266 CMR 6.04(3)(b)5.a.
through e. the Inspector shall not be required to:
a. Enter the Attic Space:
i. If it is not Readily Accessible,
ii. If access is obstructed and/or if entry could damage the property,
iii. If a Dangerous or Adverse Situation is suspected and Reported
by the Inspector.
b. Walk on the exposed and/or insulation covered framing members.
c. Collect engineering data such as the size, span, spacing, species,
section modulus, slenderness ratio and/or modulus of elasticity
of the structural members. (Engineering services).
d. Provide access to the items being inspected.
e. Observe and Report On Wood destroying insects, rodents and/or
vermin unless specifically contracted for in writing. (Independent
Pest Control/Extermination Service).
Top
(4) System: Electrical.
(a) The Inspector shall Observe the Readily Accessible and Observable
Electrical Systems and Components:
1. The exterior of the exposed service entrance conductors.
2. Exterior receptacles.
3. The service equipment, grounding system, main overcurrent device,
and the interior of the service and distribution panels (by removing
the enclosure covers).
4. The exterior of the exposed branch circuit and feeder conductors,
their overcurrent devices, and the compatibility of their ampacities
and voltages.
5. Random interior receptacles.
6. The number of branch circuits and overcurrent devices in the
panel enclosures.
(b) The Inspector shall Identify:
1. The service as being overhead or underground, cable, encased
in conduit, other.
2. The type of service, feeder, and branch-circuit conductor materials
(copper, copper-cladded aluminum, aluminum, other).
3. The type of Interior Wiring (Armored Cable, Conduit, Tubing,
Nonmetallic Cable, Knob and Tube, Flat Cable Assemblies, Other).
4. The location of the service and distribution panels and indicate
whether they are Readily Accessible and Observable.
5. The ampacity and the voltage of the main service disconnect
(30, 60, 100, 125, 150 and/or 200 amp, other service, 120, 120/240,
120/208-volt system).
6. Any of the overcurrent devices that are in the off position.
(c) The Inspector shall Report On the following Readily Accessible
and Observable Electrical Systems and Components:
1. The electrical service equipment including the service and
distribution panels.
2. Undedicated exterior and interior electrical receptacles and
polarity, grounding and ground fault protection issues (if any)
3. Any polarity or grounding issues of the receptacles required
to be tested.
4. The exposed and Readily Accessible and Observable interior
wiring.
5. Conditions that prevented him/her from inspecting any of the
items noted above.
(d) The Inspector shall:
1. Test:
a. The polarity and grounding of a representative sample of the
Readily Accessible two and three-prong receptacles throughout the
dwelling.
b. The polarity and grounding of all un-dedicated bathroom and
kitchen countertop receptacles.
c. The polarity and grounding of all Readily Accessible, non-dedicated
receptacles in the attached garage and on the exterior of inspected
structures and in unfinished basements, and check to see if they
are ground fault protected.
d. The operation of all Readily Accessible Ground-fault Circuit
Interrupters.
e. The operation of all Readily Accessible Arc Fault Current Interrupters.
f. All bathroom and kitchen countertop receptacles to see if those
receptacles are ground fault protected.
2. Note:
a. The reason(s) for not removing any panel covers.
b. The location of the service and distribution panels.
c. The presence of aluminum wiring, and
i. If the exposed and Readily Accessible and Observable aluminum
conductor terminations are coated with a termination compound,
and
ii. If the overcurrent devices are identified for use with aluminum
wire.
d. If the electrical system is attached to both the city and dwelling
side of the water piping and/or a ground rod.
e. If the water piping is not bonded to the electrical system
within the first five feet of its entry into the Basement.
f. If the neutral and equipment-ground terminal bars are bonded
to the panel enclosures.
g. The compatibility of the overcurrent devices and the size of
the protected conductor (Over-fusing).
h. The functionality of ground-fault and arc fault protected receptacles,
if any, as determined by the required testing.
i. The existence of ground fault protection devises on all bathroom,
kitchen countertop, exterior, unfinished basement, laundry and
undedicated attached garage receptacles.
(e) Exclusions: Including but not limited to 266 CMR 6.04(4)(e)1.
through 6., the Inspector shall not be required to:
1. Collect engineering data on the compatibility of the overcurrent
devices with the panel and/or determine the short circuit interrupting
current capacity. (Engineering services).
2. Determine the adequacy of the ground and/or the in place systems
to provide sufficient power to the dwelling, or reflect on the
sufficiency of the electric distribution system in the Dwelling
(Engineering/Electrical Services).
3. Insert any tool, probe, or testing device inside the panels.
4. Test or Operate any overcurrent device except Ground-fault
Circuit Interrupters and Arc Fault Interrupters.
5. Dismantle any electrical device or control other than to remove
the covers of the service and distribution panels. However, the
Inspector is not required to remove the covers of the service and
distribution panels if the panel covers are not Readily Accessible,
if there are Dangerous or Adverse Situations present, or when removal
would damage or mar any painted surface and/or covering materials.
6. Observe or Report On:
a. The quality of the conductor insulation. (Electrical Services).
b. Test for Electro-Magnetic fields. (Electrical Services).
c. Low voltage systems, doorbells, thermostats, other.
d. Smoke and carbon monoxide detectors (Seller's responsibility,
M.G.L. c. 148, § 26E and 527 CMR 31.06).
e. Telephone, security alarms, cable TV, intercoms, or other ancillary
wiring that is not a part of the primary electrical distribution
system.
f. Underground utilities, pipes, buried wires, or conduits (Dig
Safe).
Top
(5) System: Plumbing.
(a) The Inspector shall Observe:
1. The exposed Readily Accessible and Observable interior water
supply and distribution system including:
a. Piping materials, including supports and insulation.
b. Fixtures and faucets.
c. Functional Flow.
d. Leaks.
e. Cross Connections.
2. The exposed Readily Accessible and Observable exterior and
interior drain waste and vent system, including:
a. Traps; drain, waste, and vent piping; piping supports and pipe
insulation.
b. Leaks.
c. Functional Drainage.
3. Hot water systems including:
a. Water heating equipment.
b. Normal Operating Controls.
c. The presence of Automatic Safety Controls.
d. The exterior of the chimneys, thimbles and vents.
(b) The Inspector shall Identify:
1. The type(s) and condition of water distribution piping materials
(Brass, Copper, Steel, Lead, Plastic, Other).
2. The type(s) and condition of drain, waste, and vent piping
materials (Brass, Copper, Cast Iron, Galvanized, Lead, Plastic,
Steel, Other).
3. The type of water heating equipment (Gas, Electric, Oil, Tankless,
Solar, Other), and the nameplate capacity of the water heating
equipment (gallons and/or gallons per minute).
4. The location of the main shut off valve.
(c) The Inspector shall Report On
1. The water heater.
2. The exposed flue piping and the existence of thimbles in the
chimney.
3. The Readily Accessible and Observable waste and water distribution
systems.
(d) The Inspector shall:
1. Operate all plumbing fixtures where practical, including their
faucets if readily Accessible.
2. Note:
a. The presence of a pressure/temperature valve and vacuum relief
valve at the water heater.
b. The existence of Cross Connections if Readily Accessible and
Observable.
c. The existence of any visible leaks.
d. conditions that prevented him/her from inspecting any of the
Plumbing Components and Systems
(e) Exclusions: Including but not limited to 266 CMR 6.04(5)(e)1.
through 6., the Inspector shall not be required to:
1. Test the operation of any valve except Readily Accessible water
closet flush valves and fixture faucets.
2. Collect engineering data on the size of or length of water
and/or waste systems and/or remove covering materials (Engineering/Plumbing
services).
3. Report On the adequacy and/or the efficiency of the in place
systems to provide sufficient hot water to the dwelling, sufficient
water supply, or drainage for the dwelling (Engineering services).
4. State the effectiveness of anti-siphon devices (Engineering/Plumbing
services).
5. Determine whether water supply and waste disposal systems are
public or private (Seller/Seller's Representative responsibility).
6. Observe, Operate, or Report On:
a. The exterior hose bibs.
b. Water conditioning systems.
c. Fire and lawn sprinkler systems.
d. On-site or public water supply quantity and quality.
e. On-site (Title V Inspection, 310 CMR 15.00) or public waste
disposal systems.
f. Foundation sub drainage systems.
g. whirlpool tubs, except as to functional flow and functional
drainage.
h. interior of flue linings.
i. Underground utilities, pipes, buried wires, or conduits (Dig
Safe).
j. Equipment related to on-site water supply systems.
k. Water filtration Components and Systems.
Top
(6) System: Heating.
(a) The Inspector shall Observe the following permanently installed
exposed Readily Accessible and Observable heating Components and
Systems:
1. Heating equipment including, but not limited to burners, valves,
controls, circulators and fans.
2. Normal operating controls
3. Automatic Safety Controls.
4. The exterior of the chimneys, thimbles and vents.
5. Solid fuel heating devices.
6. Heating distribution systems including Readily Accessible fans,
pumps, ducts, piping and supports, dampers, insulation, air filters,
registers, radiators, fan coil units, convectors.
7. Insulation.
8. The presence of an installed heat source in each habitable
room including kitchens and bathrooms.
9. The exposed flue piping and the existence of a thimble(s).
10 The presence of a fireplace(s) and the operation of their damper(s).
(b) The Inspector shall Identify:
1. The type of energy source (Coal, Electric, Gas, Heat Pump,
Oil, Wood, Other).
2. The heating equipment (Electric, Hot Air, Hot Water, Steam,
Other).
3. The type of distribution system:
a. Piping: (Black Iron, Copper, Other).
b. Duct work: (Aluminum, Fiberglass, Steel, Other).
(c) The Inspector shall Report On the following permanently installed
and Readily Accessible and Observable heating system components:
1. The heating equipment.
2. The distribution system.
3. The flue piping and the existence of a thimble(s).
4. The fireplace hearth(s)
5. The fireplace damper(s).
(d) The Inspector shall:
1. Note:
a. The absence of an installed heat source in habitable rooms
including kitchens and bathrooms.
b. The existence of insulation.
c. The presence of exposed flues in the smoke chamber being utilized
by other appliances.
d. The operation (only) of fireplace dampers.
e. The existence of abandoned oil tanks.
f. Any observed evidence of underground oil tanks. (Exposed abandoned
oil lines, meters, etc.) Abandoned oil tanks and associated piping
must be removed per 527 CMR.
2. If possible, have the Seller and/or the Seller's Representative
Operate the systems using Normal Operating Controls. If not possible
for Seller or Seller's Representative to Operate system, the Inspector
shall Operate system using Normal Operating Controls and Report
On condition of the heating equipment.
3. Open Readily Accessible and Operable Access Panels provided
by the manufacturer or installer for routine homeowner maintenance.
(e) Exclusions: Including but not limited to 266 CMR 6.04(7)(e)1.
through 7., the Inspector shall not be required to:
1. Test and/or inspect the heat exchanger. This requires dismantling
of the furnace cover and possible removal of controls. (Engineering
services/Heating services).
2. Collect engineering data on the size of the heating equipment
and/or the size or length of the distribution systems. (Engineering/Heating
services).
3. Report On the adequacy or uniformity of the in place system(s)
to heat the dwelling and/or the various rooms within the dwelling
(Engineering/Heating services).
4. Operate heating systems when weather conditions or other circumstances
may cause equipment damage, or when the electrical and/or fuel
supply to the unit is in the off position.
5. Ignite or extinguish solid fuel and/or gas fires.
6. Identify the type of insulation coverings.
7. Observe, Identify, or Report On:
a. The interior of flues with the exception of exposed flues serving
other appliances as Observed in the smoke chamber of the fireplace.
b. Fireplace inserts flue connections.
c. Humidifiers.
d. Electronic air filters.
e. Active underground pipes, tanks, and/or ducts. However, the
Inspector must Report their existence if it is known.
f. Active oil tanks.
g. The uniformity or adequacies of heat supply to the various
rooms.
Top
(7) System: Central Air Conditioning.
(a) The Inspector shall Observe:
1. The following exposed Readily Accessible and Observable central
air conditioning components:
a. Cooling and air handling equipment.
b. Normal operating controls.
2. The following exposed Readily Accessible and Observable distribution
systems: Fans, pumps, ducts and piping, with supports, dampers,
insulation, registers, fan-coil units, condensers, the presence
of insulation on the distribution system.
(b) The Inspector shall Identify the type of distribution system
(Duct work: Aluminum, Fiberglass, Steel, Other).
(c) The Inspector shall Report On the following exposed Readily
Accessible and Observable central air conditioning components:
1. The distribution system
2. The insulation on the exposed supply ductwork.
3. The condition of the condenser and air-handling unit.
(d) The Inspector shall:
1. If possible, have the Seller and/or the Seller's Representative
Operate the systems using Normal Operating Controls
2. Open Readily Accessible Operable Access Panels provided by
the manufacturer or installer for routine homeowner maintenance
and Report On conditions Observed.
3. Note
a. Whether or not the cold gas line is insulated.
b. Whether there is, a service receptacle and a visible service
disconnect switch in the area of the condenser and air handling
equipment.
(e) Exclusions: Including but not limited to 266 CMR 6.04(7)(e)1.
through 7., the Inspector shall not be required to:
1. Collect engineering data on the size of the cooling equipment,
the size or length of the distribution systems.
2. Identify the type of insulation coverings.
3. Observe, Identify, or Report On air filters and/or their effectiveness.
4. Have the Seller and/or the Seller's Representative Operate
the cooling systems when weather conditions or other circumstances
may cause equipment damage, or when the electrical supply to the
unit is in the off position.
5. Observe, Identify, or Report On evaporator coils (Requires
dismantling of the plenum cover and possible removal of controls
which is HVAC technician work).
6. Observe, Identify, or Report On non-central air conditioners.
7. Report On the adequacy or uniformity of the in place system(s)
to cool the dwelling and/or the various rooms within the dwelling
(Engineering/Heating services).
Top
(8) System:
General Interior Conditions.
(a) The Inspector shall Observe:
1. Walls, ceiling, and floors.
2. Steps, stairways, balconies, hand and guard railings.
3. Counter tops and a representative number of cabinets.
4. A representative number of doors and windows.
5. Separation walls, ceilings, and doors between a dwelling unit
and an attached garage or another dwelling unit.
(b) The Inspector shall Identify:
1. The type of exposed floor material (brick, carpet, ceramic
tile, linoleum, slate, vinyl tile, wood, other).
2. The type of exposed wall materials (brick, ceramic tile, fiberglass,
laminates, paneled, plaster, gypsum wallboard, plastic tile, other).
3. The type of exposed ceiling materials (acoustical tile, gypsum
wallboard, plaster, wood, other).
(c) The Inspector shall Report On:
1. The floor.
2. The walls.
3. The ceilings.
4. The condition of the interior stairs, hand and guard railings.
5. Signs of water penetration.
6. The interior doors Observed and tested.
7. The windows
(d) The Inspector shall operate a representative number of doors,
windows, and cabinets
(e) Exclusions: Including but not limited to 266 CMR 6.04(8)(e)1.
and 2., the Inspector shall not be required to:
1. Observe and Report On the following:
a. Paint, wallpaper, and other finish treatments on the interior
walls, ceilings, and floors.
b. Draperies, blinds, or other window treatments.
c. Household appliances.
2. Determine the fire safety rating of any walls, ceilings, and
doors between a dwelling unit and an attached garage or another
dwelling unit.
(9) System: Insulation and Ventilation.
(a) The Inspector shall Observe the following Readily Accessible
and Observable Components and Systems:
1. Exposed insulation in unfinished spaces.
2. Ventilation of Attics and Under Floor Crawl Space areas.
3. Bathroom venting systems
(b) The Inspector shall Identify:
1. The type of ventilation in the attic space (None, Ridge, Soffit,
Area, Power Vent, Gable, Eave, Mushroom, Turbine, Other).
2. The existence and/or absence of bathroom ventilation other
than a window(s).
(c) The Inspector shall Report On the following Readily Accessible
and Observable Components and Systems:
1. Exposed insulation in unfinished spaces.
2. Ventilation of attics and Under Floor Crawl Space areas.
3. Bathroom venting systems.
(d) The Inspector shall Note:
1. The absence of insulation in unfinished space at Conditioned
Surfaces.
2. The absence of ventilation of an Under Floor Crawl Space.
(e) Exclusions: Including but not limited to 266 CMR 6.04(9)(e)1.
through 5., the Inspector shall not be required to Observe and
Report On the following:
1. The type(s) and/or amounts of insulation and/or its material
make-up.
2. Concealed insulation and vapor retarders.
3. Venting equipment that is integral with household appliances.
4. The venting of kitchens.
5. The adequacy, uniformity and capacity of the in place system(s)
to ventilate the various areas of the dwelling (Engineering/Heating
services).
Top
6.05: General Limitations and Exclusions of the Home Inspection
(1) General Limitations.
(a) Home Inspections done in accordance with the standards set
forth in 266 CMR 6.04 are visual and not Technically Exhaustive.
(b) The Home Inspections standards set forth in 266 CMR 6.04 are
applicable to Residential Buildings with four or less Dwelling
units under one roof and their attached garages.
(2) General Exclusions.
(a) Inspectors shall not be required to Report On:
1. The remaining life expectancy of any component or system.
2. The causes of the need for repair.
3. The materials for corrections of the problem.
4. The methods of repair other than to indicated the repair should
comply with applicable requirements of the governing codes and
sound construction practices.
5. Compliance or non-compliance with applicable regulatory requirements
unless specifically contracted for in writing.
6. Any component or system not covered by 266 CMR 6.04.
7. Cosmetic items.
8. Items that are not Readily Accessible and Observable, underground
items, or items not permanently installed.
9. Systems or Components specifically excluded by Client (noted
in writing in the Contract or in the Report).
(b) Inspectors shall not be required to perform or provide any
of the following under the Home Inspection specified in 266 CMR
6.04:
1. Offer warranties, guarantees and/or insurance policies of any
kind on the property being inspected.
2. Collect any engineering data (the size of structural members
and/or the output of mechanical and/or electrical equipment).
3. Inspect spaces that are not Readily Accessible and Observable.
Enter any area or perform any procedure, which may damage the property
or its components, or be dangerous and unsafe to the Inspector
or other persons, as determined by and Reported by the Inspector.
4. Disturb or move insulation, stored and/or personal items, furniture,
equipment, plant life, soil, snow, ice, or debris that obstructs
access or visibility.
5. Determine the effectiveness of any system installed to control
or remove suspected hazardous substances
6. Predict future conditions, including but not limited to failure
of Components. (See Additional Services)
7. Project operating costs of Components.
8. Determine extent or magnitude of damage or failures noted.
9. Operate any System or Component which does not respond to normal
operating controls.
10. Test for radon gas.
11. Determine the presence or absence of pests including but not
limited to: rodents or wood destroying insects.
12. Determine the energy efficiency of the dwelling as a whole
or any individual system or component within the dwelling.
13. Perform Environmental Services including determining the presence
or verifying the absence of any micro organisms or suspected hazardous
substances including, but not limited to, carbon monoxide, latent
surface and/or subsurface Volatile Organic Compounds, PCB's, asbestos,
UFFI, toxins, allergens, molds, carcinogens, lead paint, radon
gas, electromagnetic radiation, noise, odors, or any contaminants
in soil, water, air wet lands and/or any other environmental hazard
not listed in 266 CMR 6.05(2)(a) and (b).
14. Evaluate acoustical characteristics of any system or component.
15. Inspect surface and subsurface soil conditions.
Top
6.06: Prohibitions
Inspectors are prohibited from:
(1) Reporting on the market value of property or its marketability
and/or the suitability of the property for any use.
(2) Advising their Client about the advisability or inadvisability
of the purchase of the property.
(3) Testing Automatic Safety Controls.
(4) Activating the sump pumps and/or dehumidifiers.
(5) Offering or performing any act or service contrary to law
and/or these regulations.
(6) Determining the cost of repairs of any item noted in their
Report and/or inspected by them and/or their firm.
(7) Offering to make and/or perform any repair, provide any remedy:
including but not limited to performing engineering, architectural,
surveying, plumbing, electrical and heating services, pest control
(treatment), urea formaldehyde or any other job function requiring
an occupational license and/or registration (in the jurisdiction
where the inspection had taken place) on a Dwelling, and/or Residential
Building inspected by his/her firm. The only exception is if those
repairs and/or services are part of a negotiated settlement of
a complaint and/or claim against the Inspector and/or the firm
he/she/represents.
(8) However, nothing in this section shall prohibit the Inspector
and/or his/her/firm from offering consulting services on a Dwelling,
and/or Residential Building his/her firm has not inspected as long
as the consulting service is not pursuant to the sale and/or transfer
of the property and/or dwelling.
(9) Operating any system or component that is shut down or otherwise
inoperable. (However, the Inspector shall recommend the Seller
and/or the Seller's Representative demonstrate that those systems
and/or components are functional).
(10) Turn on any electrical or fuel supply and/or devices that
are shut down. (However, the Inspector shall recommend the Seller
and/or the Seller's Representative demonstrate that those systems
and/or components are functional).
Top
6.07: Optional Fee Based Services
There are certain risks inherent in the purchase of property and
a Home Inspection is inherently limited in its scope and depth.
The information gained from Home Inspection conforming to 266 CMR
6.04 may reduce some of those risks, but the Home Inspection is
not intended to provide the Client with protection from all of
the risks involved.
The Home Inspector may provide Optional Fee Based Services addressing
items including, but not limited to, those excluded in 266 CMR
6.04 provided the service is specifically contracted for in writing
and/or included in the Report, and do not include the physical
repair, abatement, or treatment to the Dwelling, and/or Residential
Building being inspected, and is not prohibited under 266 CMR 6.06.
To offer any such services that require an occupational license
and/or registration, the Inspector shall hold a valid registration
and/or occupational license in the jurisdiction where the inspection
is taking place. The Inspector shall inform the Client in writing
that he/she is so registered/licensed and is therefore qualified
to go beyond the standards of 266 CMR 6.04.
Top
REGULATORY AUTHORITY
266 CMR 6.00: M.G.L. c. 13, § 96 and c. 112, §§ 221 through 226 |